Page 1 |
Save page Remove page | Previous | 1 of 126 | Next |
|
small (250x250 max)
medium (500x500 max)
large ( > 500x500)
Full Resolution
All (PDF)
|
This page
All
Subset |
EFFECTS OF TALKER VARIABILITY IN COCHLEAR IMPLANTS
by
Yi-ping Chang
_____________________________________________________________________
A Dissertation Presented to the
FACULTY OF THE GRADUATE SCHOOL
UNIVERSITY OF SOUTHERN CALIFORNIA
In Partial Fulfillment of the
Requirements for the Degree
DOCTOR OF PHILOSOPHY
(BIOMEDICAL ENGINEERING)
August 2009
Copyright 2009 Yi-ping Chang
Object Description
| Title | Effects of talker variability in cochlear implants |
| Author | Chang, Yi-ping |
| Author email | yipingch@usc.edu; yiping.chang@gmail.com |
| Degree | Doctor of Philosophy |
| Document type | Dissertation |
| Degree program | Biomedical Engineering |
| School | Viterbi School of Engineering |
| Date defended/completed | 2009-05-12 |
| Date submitted | 2009 |
| Restricted until | Unrestricted |
| Date published | 2009-06-22 |
| Advisor (committee chair) | Fu, Qian-Jie |
| Advisor (committee member) |
D'Argenio, David Shung, K. Kirk Shannon, Robert Narayanan, Shrikanth |
| Abstract | Speech perception is influenced by many factors; differences in talker characteristics also significantly influence speech perception. Because speech understanding is fairly robust to variations in pronunciation, researchers have theorized that a "speaker normalization" process occurs, in which multiple talkers' speech patterns are normalized to a target pattern. However, effects of "talker variability" may also be produced, in which speech recognition performance worsens with multiple talkers, relative to that with a single talker. Due to partial loss of talker voice information in spectrally degraded speech as experienced by cochlear implant users, the talker variability effects in cochlear implant speech may be more complex and the underlying mechanism is still not clear.; The first part of this study is perceptual experiments investigating talker variability effects in cochlear implants. A baseline experiment with cochlear implant users showed a significant talker variability effect. Then a series experiments was conducted with normal hearing subjects in simulations to investigate effects of number of talkers, talker set, background noise, carrier, spectral resolution, and number of successive talker-specific stimuli.; In the second part of this study, we compared talker variability effects with talker discrimination performance. The results revealed a strong correlation between talker variability effects and talker discrimination performance. The most prominent talker variability effects were observed in cochlear implant users with moderate levels of talker discrimination performance. Talker variability effects were relatively small in cochlear implant users with relatively good or poor talker discrimination performance.; The third part of this study is acoustic analyses and modeling of talker variability effects in cochlear implants. The acoustic distance between vowel stimuli and scatter indices of vowel pairs were calculated based on the temporal spectral envelope of the vocoder processed vowel stimuli. To account for talker variability effects, modifications were made respectively for single- and multi-talker context. In general, the normalized average acoustic distance could well predict the overall performance and talker variability effects. However, the prediction for the detailed confusion patterns showed some mixed results. The results are consistent with the assumption that talker variability effects are caused by listeners’ adaptation to talker characteristics in a single-talker context. |
| Keyword | speech perception; cochlear implant; talker variability effects; auditory prostheses |
| Language | English |
| Part of collection | University of Southern California dissertations and theses |
| Publisher (of the original version) | University of Southern California |
| Place of publication (of the original version) | Los Angeles, California |
| Publisher (of the digital version) | University of Southern California. Libraries |
| Provenance | Electronically uploaded by the author |
| Type | texts |
| Legacy record ID | usctheses-m2303 |
| Rights | Chang, Yi-ping |
| Repository name | Libraries, University of Southern California |
| Repository address | Los Angeles, California |
| Repository email | http://www.usc.edu/isd/libraries/services/ask_a_librarian/email/ |
| Filename | etd-Chang-2982 |
| Archival file | uscthesesreloadpub_Volume55/etd-Chang-2982.pdf |
Description
| Title | Page 1 |
| Full text | EFFECTS OF TALKER VARIABILITY IN COCHLEAR IMPLANTS by Yi-ping Chang _____________________________________________________________________ A Dissertation Presented to the FACULTY OF THE GRADUATE SCHOOL UNIVERSITY OF SOUTHERN CALIFORNIA In Partial Fulfillment of the Requirements for the Degree DOCTOR OF PHILOSOPHY (BIOMEDICAL ENGINEERING) August 2009 Copyright 2009 Yi-ping Chang |
Comments
Post a Comment for Page 1

