Page 1 |
Save page Remove page | Previous | 1 of 138 | Next |
|
small (250x250 max)
medium (500x500 max)
Large (1000x1000 max)
Extra Large
large ( > 500x500)
Full Resolution
All (PDF)
|
This page
All
|
FAST ITERATIVE IMAGE RECONSTRUCTION FOR 3D PET AND ITS EXTENSION TO TIME-OF-FLIGHT PET by Sanghee Cho A Dissertation Presented to the FACULTY OF THE GRADUATE SCHOOL UNIVERSITY OF SOUTHERN CALIFORNIA In Partial Fulfillment of the Requirements for the Degree DOCTOR OF PHILOSOPHY (ELECTRICAL ENGINEERING) December 2008 Copyright 2008 Sanghee Cho
Object Description
Title | Fast iterative image reconstruction for 3D PET and its extension to time-of-flight PET |
Author | Cho, Sang Hee |
Author email | sanghcho@sipi.usc.edu; scho.2000@gmail.com |
Degree | Doctor of Philosophy |
Document type | Dissertation |
Degree program | Electrical Engineering |
School | Viterbi School of Engineering |
Date defended/completed | 2008-07-31 |
Date submitted | 2008 |
Restricted until | Restricted until 5 Oct. 2009. |
Date published | 2009-10-05 |
Advisor (committee chair) | Leahy, Richard M. |
Advisor (committee member) |
Kuo, C.-C. Jay Singh, Manbir Chatziioannou, Arion |
Abstract | Positron emission tomography (PET) is a functional biomedical imaging technique that provides in vivo information about physiological processes within the body by reconstructing the 3D distribution of a adiolabelled tracer. It is challenging to estimate the tracer distribution accurately since photon-limited PET data have high statistical variance. Statistical iterative reconstruction methods have shown uperior image quality and better quantitative results compared to analytical reconstruction methods.However, the iterative methods involve huge computational loads, particularly for fully 3D PET, consequently limiting their routine use in practice. Clinical 3D time-of-flight (TOF) PET scanners, which become available due to recent developments of fast scintillators, involve an even higher computational cost for image reconstruction because of extra TOF information. A successful pragmatic approach that reduces computation cost for fully 3D PET is to use Fourier rebinning (FORE), reducing 3D PET data to 2D data, combined with a 2D reconstruction method such as the ordered subsets expectation-maximization (OSEM) algorithm. The combination of FORE and 2D OSEM is now routinely used in both clinical and small animal imaging systems. However, data dimensionality reduction using FORE can result in a loss in resolution or noise performance. In the first part of this dissertation, we develop fast projectors that map a 3D image into 3D PET data by using the exact inverse (Fourier) rebinning operator. The inverse rebinning operator is used for calculating 3D PET data from 2D PET data, and combined with a 2D projector to construct a fast 3D projection operator. The inverse rebinning operator is implemented cost-effectively using the fast Fourier transform (FFT), so that the computation time is reduced by an order of magnitude. We utilize this fast projector in the context of fully 3D PET maximum a posteriori (MAP) reconstruction methods.; We reduced the reconstruction time substantially while retaining the resolution recovery properties. In the second part of this dissertation, we develop fast 3D image reconstruction methods for TOF PET. We derive a unified framework based on a generalized projection slice theorem. In this framework, we derive mapping equations between different data sets such as 3D TOF, 2D TOF, 3D non TOF and 2D non TOF PET data. Using the mapping equations, we develop a TOF Fourier rebinning method which rebins 3D TOF PET data to 2D TOF data. We also develop other exact and approximate rebinning methods where 3D TOF PET data are rebinned to 2D or 3D non TOF data. Our simulation studies showed that the reconstructed images after TOF Fourier rebinning give superior resolution-variance properties compared to the non TOF case where the TOF information is ignored. |
Keyword | Fourier rebinning; fully 3D PET; inverse rebinning; iterative reconstruction; time-of-flight PET |
Language | English |
Part of collection | University of Southern California dissertations and theses |
Publisher (of the original version) | University of Southern California |
Place of publication (of the original version) | Los Angeles, California |
Publisher (of the digital version) | University of Southern California. Libraries |
Provenance | Electronically uploaded by the author |
Type | texts |
Legacy record ID | usctheses-m1623 |
Contributing entity | University of Southern California |
Rights | Cho, Sang Hee |
Repository name | Libraries, University of Southern California |
Repository address | Los Angeles, California |
Repository email | cisadmin@lib.usc.edu |
Filename | etd-CHO-2369 |
Archival file | uscthesesreloadpub_Volume14/etd-CHO-2369.pdf |
Description
Title | Page 1 |
Contributing entity | University of Southern California |
Repository email | cisadmin@lib.usc.edu |
Full text | FAST ITERATIVE IMAGE RECONSTRUCTION FOR 3D PET AND ITS EXTENSION TO TIME-OF-FLIGHT PET by Sanghee Cho A Dissertation Presented to the FACULTY OF THE GRADUATE SCHOOL UNIVERSITY OF SOUTHERN CALIFORNIA In Partial Fulfillment of the Requirements for the Degree DOCTOR OF PHILOSOPHY (ELECTRICAL ENGINEERING) December 2008 Copyright 2008 Sanghee Cho |