CALIBRATION AND DATA ACCURACY RESEARCH OF THE SCHIERLE SHAKE TABLE by Yunzhi Huang A Thesis Presented to the FACULTY OF THE SCHOOL OF ARCHITECTURE UNIVERSITY OF SOUTHERN CALIFORNIA In Partial Fulfillment of the Requirements for the Degree MASTER OF BUILDING SCIENCE August 2008 Copyright 2008 Yunzhi Huang
Object Description
Title | Calibration and data accuracy research of the Schierle shake table |
Author | Huang, Yunzhi |
Author email | yunzhi.huang@gmail.com; yunzhihu@usc.edu |
Degree | Master of Building Science |
Document type | Thesis |
Degree program | Building Science |
School | School of Architecture |
Date defended/completed | 2008-03-23 |
Date submitted | 2008 |
Restricted until | Unrestricted |
Date published | 2008-08-03 |
Advisor (committee chair) | Schierle, G. Goetz |
Advisor (committee member) |
Pingree, Joseph E. Satorius, Edgar H. |
Abstract | This Thesis is about the calibration method of a small-scale single-axis shake table and its realization by programming user-friendly software for calibration and shaking using LabVIEW.; In order to verify the reliability of the calibration, two methodologies were used. The first set of data is gained from the accelerometer by attaching it directly on the shake table platform. Both a single sine wave and a scaled real seismic wave were tested. After calibration, both sets of collected data from the accelerometer were almost the same as the input.; After calibration, the G. G. Schierle shake table is valuable to the School of Architecture as a teaching and research tool. It can be used to demonstrate the structure behavior visually and can be used in an experiment to get reliable numerical data for structure research and study. |
Keyword | single-axis shake table; calibration; vibration system calibration |
Language | English |
Part of collection | University of Southern California dissertations and theses |
Publisher (of the original version) | University of Southern California |
Place of publication (of the original version) | Los Angeles, California |
Publisher (of the digital version) | University of Southern California. Libraries |
Provenance | Electronically uploaded by the author |
Type | texts |
Legacy record ID | usctheses-m1526 |
Contributing entity | University of Southern California |
Rights | Huang, Yunzhi |
Repository name | Libraries, University of Southern California |
Repository address | Los Angeles, California |
Repository email | cisadmin@lib.usc.edu |
Filename | etd-Huang-2308 |
Archival file | uscthesesreloadpub_Volume14/etd-Huang-2308-0.pdf |
Description
Title | Page 1 |
Contributing entity | University of Southern California |
Repository email | cisadmin@lib.usc.edu |
Full text | CALIBRATION AND DATA ACCURACY RESEARCH OF THE SCHIERLE SHAKE TABLE by Yunzhi Huang A Thesis Presented to the FACULTY OF THE SCHOOL OF ARCHITECTURE UNIVERSITY OF SOUTHERN CALIFORNIA In Partial Fulfillment of the Requirements for the Degree MASTER OF BUILDING SCIENCE August 2008 Copyright 2008 Yunzhi Huang |